QBCC LicenceQBCC 15560197 ABN 95 681 636 706 Public & Products LiabilityPL $20M WorkCover QLD Insured Welding to AS/NZS 1554.1

Notes from the workshop

Stairs, balustrades and access platforms: the standards your steel has to meet

Steel stairs and barriers answer to more than one rulebook, and which one applies changes the geometry. It has to be settled before detailing, not at inspection.

Steel stair stringers set up in the TMF Welding workshop, Brisbane

In this article

The short answer

Steel stairs, landings and barriers sit under different rules depending on what they serve. Stairs and barriers in buildings people occupy follow the National Construction Code and the standards it references, including the barrier loads in AS/NZS 1170.1. Industrial access steel — plant platforms, walkways, ladders and the stairs serving them — is designed to AS 1657. Which one applies decides the geometry, the infill and the loads, so it has to be settled before detailing starts.

Stairs and balustrades look like simple steel. They are the most rule-bound thing a fabricator makes, and the rules are not all in one place. Getting the wrong rulebook is not a detail — it changes the going and riser, the handrail height, what can be used as infill and what loads the thing has to carry. Discovered after fabrication, it is a remake.

Two different worlds

Building work. Stairs, landings, ramps and barriers in buildings people occupy are governed by the National Construction Code and the standards it references. That covers dimensional consistency in a flight, slip resistance, handrail and barrier requirements, and the limits on openings and climbable elements in a barrier. Barrier loads come from AS/NZS 1170.1, and the load depends on what the barrier is protecting — a domestic balcony and a grandstand are not the same number.

Industrial access. Platforms, walkways, ladders and the stairs serving plant and equipment are designed to AS 1657, the standard for fixed platforms, walkways, stairways and ladders. It sets its own geometry, guardrailing and loading rules, and they are not the same as the building ones. A plant platform detailed to building stair geometry can fail an AS 1657 review, and the reverse is just as true.

Some projects have both, in the same building, sometimes on the same level. Which standard applies to which element belongs in the specification.

What settles the answer

Three questions get you most of the way:

  • Who uses it? Occupants and the public, or workers reaching plant. That is the main fork.
  • How far is the fall? Fall height drives whether a barrier is required at all and what it has to do. It is also what turns a handrail into a barrier, which are not the same thing.
  • Who signs it off? A building certifier, a structural engineer, or both. Knowing who is checking tells you what evidence has to exist.

Where these jobs go wrong

The flight does not match the drawing because the slab does not. Stair geometry has to be consistent within a flight, and a floor-to-floor dimension that is thirty millimetres off in the concrete shows up as an uneven riser in the steel. Site measure before fabrication, every time, where the stair lands on built work.

Infill chosen for looks, not for compliance. Wire, glass, perforated sheet and vertical bar all behave differently against opening and climbability requirements, and glass brings its own standard. Settle the infill before the frame is detailed, because it changes the frame.

Handrail treated as decoration. A handrail people grip has requirements for height, continuity, graspability and what happens at the ends. Terminations at the top and bottom of a flight are the most commonly missed part of a stair package.

Fixings designed last. A stair is only as good as what it is bolted to. Fixings into masonry, existing concrete or lightweight framing need designing, and where the substrate is unknown the honest answer at quote stage is a provisional item, not a guess.

What we ask for on a stair or balustrade package

  • Which standard applies — building work or AS 1657 access
  • Fall heights, and where a barrier is required
  • Nominated infill type and any colour or finish requirement
  • Floor-to-floor dimensions, and permission to site measure before fabrication
  • Substrate details where the steel fixes to existing work
  • Who certifies, and whether certification is included in the package
  • Whether the finish is galvanised, painted or duplex — it changes the detailing

Why we push to measure on site

A stair made to the drawing and a stair made to the building are two different stairs whenever the building moved. Measuring costs an hour. Remaking a flight of stringers costs a week and a crane booking. We would rather have the hour.

Common questions

Does AS 1657 apply to stairs inside an office building?

Generally not. AS 1657 covers fixed platforms, walkways, stairways and ladders for access to plant and equipment. Stairs and barriers serving occupants of a building are governed by the National Construction Code and the standards it references. Some projects contain both, so the specification should say which applies where.

Who certifies a steel balustrade?

It depends on the project. A building certifier signs off compliance with the National Construction Code, and a structural engineer may be needed for the design and the fixings, particularly where the barrier is loaded or fixed to existing structure. Agree who is certifying before the package is fabricated, and whether that certification sits inside the steel package or outside it.

Can steel stairs be fabricated from the drawings alone?

They can, but where a stair lands on concrete or existing structure it is far safer to site measure first. Stair geometry has to stay consistent within a flight, so a floor-to-floor dimension that differs from the drawing turns into an uneven riser. An hour with a tape before fabrication avoids remaking the stringers.

What loads does a balustrade have to carry?

Barrier loads come from AS/NZS 1170.1 and depend on what the barrier serves — the figure for a domestic balcony is not the figure for a public assembly area. The design engineer nominates the loading case, and the fabricator details the frame, infill and fixings to suit it.

Send us a stair or balustrade package